AWG 14 K Type Thermocouple Compensating / Compensation Cable FEP Insulation

نموذج رقم.
K Type Thermocouple Compensating Cable

Material Shape
Round Wire

Range of Application

شهادة
شهادة ISO9001, هذه, بنفايات

ماركة
Tankii

Section Area
0.5mm2, 0.75mm2, 1.0mm2

درجة
أنا, II, III

إستعمال
Thermocouple Sensors

Types
K,T,J,N,ب,س,ر

Shape
Single, Pair, Stranded

Insulation
Fiberglass, PVC, PTFE, Silicon Rubber

Temperature Range
-60-1100

Shield
as You Required

Colour
Requirement

علامة تجارية
HUONA

حزمة النقل
According to Clients Requirements

تخصيص
According to clients requirements

أصل
Shanghai, الصين

رمز النظام المنسق
7505220000

وصف

ANSI Standard AWG 14 Type K Thermocouple Compensation Cable FEP Insulation

Huona produces different types of compensated cable for thermocouple, such as KX type, NX, EX, JX, NC, TX, SC / RC, KCA, KCB. We also produce all cables with insulation such as PVC, PTFE, Silicone and fiberglass.
The compensated cable is mainly used in thermal measurement instrumentation. If the temperature changes, the cable responds with a small voltage that passes to the thermocouple it is connected to and we already have the measurement.

The thermocouple compensation cables can also be termed as instrumentation cables, since they are used for process temperature measurement. The construction is similar to pair instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control. The thermocouple and pyrometer are electrically conducted by thermocouple extension cables / thermocouple compensating cables. The conductors used for these thermocouple cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature.

Our plant mainly manufacture type KX,NX,EX,JX,NC,TX,SC/RC,KCA,KCB compensating wire for thermocouple, and they are used in temperature measurement instruments and cables. Our thermocouple compensating products are all made abiding by GB/T 4990-2010 ‘Alloy wires of extension and compensating cables for thermocouples’ (Chinese National Standard), and also IEC584-3 ‘Thermocouple part 3-compensating wire’ (International standard).

The representing of the comp. wire: thermocouple code+C/X , e.g. SC, KX
X: Short for extension, means that the compensation wire’s alloy is as the same as the the alloy of the thermocouple
ج: Short for compensation, means that the compensation wire’s alloy has similar characters with the thermocouple’s alloy in a certain temperature range.

Type K Thermocouple Bare Wire

Type K (CHROMEL vs ALUMEL ) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures.

1. Chemical جomposition

موادChemical composition (%)
NiCrSiMnAl
KP(Chromel)9010
KN(Alumel)95 1-20.5-1.51-1.5

2. Physical properties and Mechnical properties

مواد

Density(g/cm3)

Melting point(º ج)

Tensile Strength(Mpa)

Volume resistivity(μΩ.cm)

Elongation rate (%)

KP(Chromel)8.51427>49070.6(20º ج)>10
KN(Alumel)8.61399>39029.4(20º ج)>15

3. EMF Value range at different temperature

موادEMF value Vs Pt(μV)
100º ج200º ج300º ج400º ج500º ج600º ج
KP(Chromel)2816~28965938~60189298~937812729~1282116156~1626619532~19676
KN(Alumel)1218~12622140~21802849~28933600~36444403~44635271~5331

EMF value Vs Pt(μV)
700º ج800º ج900º ج1000º ج1100º ج
22845~2299926064~2624629223~2941132313~3252535336~35548
6167~62477080~71607959~80598807~89079617~9737

Type K Extension Cable Chromel / Alumel Material FEP insulation

تحديد

1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple copper wire Classification
1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, إلخ.
2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, ر, ب, K, E, J, T, N and L, heating cable, control cable and so on.

Thermocouple variety and index

Thermocouple Variety and Index
VarietyاكتبMeasurement Range(°C)
NiCr-NiSiK-200-1300
NiCr-CuNiE-200-900
Fe-CuNiJ-40-750
Cu-CuNiT-200-350
NiCrSi-NiSiN-200-1300
NiCr-AuFe0.07NiCr-AuFe0.07-270-0

3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire

Dimensions / Tolerance mm ) : 4.0+-0.25

Color code & initial calibration tolerances for thermocouple wire:

Thermocouple TypeANSI Color CodeInitial Calibration Tolerances
Wire AlloysCalibration+/-
موصل
السترةTemperature Rangeمعيار
Limits
Special
Limits
CHROMEL(+) vs.
ALUMEL(-)
KYellow/RedBrown-200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C
± 2%
±2.2°C
±2.2°C
± .75%
±1.1°C
± .4%

Color Code & Initial Calibration Tolerance for Extension Wire:

Extension typeANSI Color CodeInitial Calibration Tolerances
Wire AlloysCalibration+/-
موصل
السترةTemperature Rangeمعيار
Limits
Special
Limits
حديد (+) vs. Constantan(-)JXWhite/Redأسود0°C to +200°C±2.2°C±1.1°C
CHROMEL (+) vs. ALUMEL (-)KXYellow/RedYellow0°C to +200°C±2.2°C±1.1°C
نحاس(+) vs. Constantan(-)TXBlue/Redأزرق-60°C to +100°C±1.1°C± .5°C
CHROMEL(+) vs. Constantan(-)EXPurple/RedPurple0°C to +200°C±1.7°C±1.1°C

PVC-PVC Physical Properties:

CharacteristicsInsulationالسترة
Abrasion ResistanceGoodGood
Cut Through ResistanceGoodGood
Moisture ResistanceExcellentExcellent
Solder Iron ResistancePoorPoor
Service Temperature

105ºC continuous

150ºC single

105ºC continuous

150ºC single

Flame TestSelf-extinguishingSelf-extinguishing

AWG 14 K Type Thermocouple Compensating / Compensation Cable FEP Insulation
AWG 14 K Type Thermocouple Compensating / Compensation Cable FEP Insulation