Ce Approved Wire XLPE Insulation PVC Sheathed Wire, سلك الطاقة

نموذج رقم.
YJV22/YJV32/YJV

Wire Core Material
Bare Copper Wire

شهادة
ISO, CCC, هذه, بنفايات, VDE, SABS

نموذج
Various

ماركة
Jiapu

Armored Method
Swa or Sta or Awa

معيار
IEC, NFC, ASTM, Bis, DIN and So on

علامة تجارية
Jiapu

حزمة النقل
Export Wooden Drums

تخصيص
IEC ASTM BS DIN, Any standard

أصل
الصين

رمز النظام المنسق
8544492100

وصف

CE approved wire XLPE Insulation PVC Sheathed Wire, سلك الطاقة
Ce Approved Wire XLPE Insulation PVC Sheathed Wire, سلك الطاقة

Copper/XLPE Insulated / SWA /Power Cable (0.6/1KV, 6/35KV) تخصيص:

Number Of core: 1core to 5 cores, 3+1 cores, 3+2 cores, 4+1 cores

الجهد االكهربى: 0.6/1KV, 1/35KV

1) نحاس (aluminium) cores / XLPE insulated / PVC(PE) sheathed power cable

2) نحاس (aluminium) cores /XLPE insulated /steel tape armored/ PVC ( PE) sheathed power cable

3) نحاس (aluminium) cores /XLPE insulated / thin steel wire armored/ PVC ( PE) sheathed power cable

4) نحاس (aluminium) cores /XLPE insulated / thick steel wire armored/ PVC ( PE) sheathed power cable

The products can be produced according to our factory specification which is equivalent to the standard IEC, ASTM, من. BS. Their structures are simple. The permissible maximum operating temperature is 90C. It is convenient for using, and they can be laid with no restriction of different elevation.

Remarks: Including products for flame retardant, fire resistant and termite-proof
Packing: Export wooden drums

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. وزن
Al ConductorCu Conductor
No. X mm 2ممممممممممممممkg/mkg/m
3 X 2562.50.11.20.21.937.91.872.32
3 X 356.92.50.11.30.5241.52.12.73
3 X508.22.50.11.30.5244.32.373.22
3 X 709.72.50.11.40.52.147.92.774
3 X 9511.32.50.11.40.52.251.63.214.91
3 X 12012.82.50.11.50.52.455.43.695.84
3 X 15014.22.50.11.50.52.558.64.156.85
3 X 18515.92.50.11.50.52.662.54.738.11
3 X 24018.32.60.11.60.52.768.55.6210.05
3 X 30020.42.80.11.70.52.974.56.5512.11
3 X 40023.230.11.90.83.283.68.7815.86
3 X 50026.43.20.12.10.83.49310.5218.85
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. وزن
Al ConductorCu Conductor
No. X mm 2ممممممممممممممkg/mkg/m
3 X 2563.40.11.30.5243.42.162.61
3 X 356.93.40.11.30.5245.42.362.99
3 X508.23.40.11.40.52.248.82.693.54
3 X 709.73.40.11.50.52.352.43.14.33
3 X 9511.33.40.11.50.52.456.13.565.26
3 X 12012.83.40.11.50.52.559.54.046.19
3 X 15014.23.40.11.50.52.662.74.497.19
3 X 18515.93.40.11.60.52.666.65.128.49
3 X 24018.33.40.11.70.52.872.45.9910.42
3 X 30020.43.40.11.80.5377.56.8612.42
3 X 40023.23.40.11.90.83.285.48.9716.05
3 X 50026.43.40.120.83.493.710.6519.5
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. وزن
Al ConductorCu Conductor
No. X mm 2ممممممممممممممkg/mkg/m
3 X 2564.50.11.40.52.148.62.532.98
3 X 356.94.50.11.40.52.250.72.763.39
3 X508.24.50.11.50.52.353.93.13.95
3 X 709.74.50.11.50.52.457.43.514.74
3 X 9511.34.50.11.50.52.661.24.055.75
3 X 12012.84.50.11.60.52.664.74.566.72
3 X 15014.24.50.11.60.52.767.95.047.74
3 X 18515.94.50.11.70.52.871.95.669.04
3 X 24018.34.50.11.80.5377.76.5611
3 X 30020.44.50.11.90.83.284.18.3913.96
3 X 40023.24.50.120.83.390.59.7116.79
3 X 50026.44.50.12.10.83.598.811.4520.57
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. وزن
Al ConductorCu Conductor
No. X mm 2ممممممممممممممkg/mkg/m
3 X 25
3 X 356.95.50.11.50.52.455.63.143.77
3 X508.25.50.11.50.52.558.63.494.34
3 X 709.75.50.11.50.52.662.13.935.16
3 X 9511.35.50.11.60.52.665.74.466.16
3 X 12012.85.50.11.70.52.769.457.15
3 X 15014.25.50.11.70.52.872.65.498.19
3 X 18515.95.50.11.80.5376.96.169.53
3 X 24018.35.50.11.90.83.283.97.8712.31
3 X 30020.45.50.120.83.288.68.9614.52
3 X 40023.25.50.12.10.83.595.410.3517.43
3 X 50026.45.50.12.20.83.7103.712.4520.23
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor Nominal Diameter of Conductor Nominal Thickness of Insulation Nominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. وزن
Al ConductorCu Conductor
No. X mm 2ممممممممممممممkg/mkg/m
3 X 25
3 X 35
3 X508.280.11.70.52.870.44.565.41
3 X 709.780.11.70.52.973.95.046.26
3 X 9511.380.11.80.5377.75.627.32
3 X 12012.880.11.90.83.282.86.999.15
3 X 15014.280.11.90.83.285.87.5610.26
3 X 18515.980.120.83.389.98.311.67
3 X 24018.380.12.10.83.595.79.3613.79
3 X 30020.480.12.20.83.6100.610.5116.07
3 X 40023.280.12.30.83.8107.211.9919.07
3 X 50026.480.12.40.84120.114.1523.85

ورشة عمل
Ce Approved Wire XLPE Insulation PVC Sheathed Wire, سلك الطاقة
Shipment
Ce Approved Wire XLPE Insulation PVC Sheathed Wire, سلك الطاقة
QA&QC
Ce Approved Wire XLPE Insulation PVC Sheathed Wire, سلك الطاقة
CUSTOMER VISIT
Ce Approved Wire XLPE Insulation PVC Sheathed Wire, سلك الطاقة

التعليمات

1. How many years has Henan Jiapu Cable Group been in production?

Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,الصين

2. What kinds of products does Jiapu Cable manufacture?

1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;

2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;

3)PVC Insulated (Flexible ) الأسلاك ;

4) PVC Insulated and Sheathed (Armoured) سلك الطاقة;

5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) سلك الطاقة;

6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

3. What kind of certifications do you have?

SABS, هذه, ISO9001-2000, اس جي اس

4.Which markets do you involve mainly in?

Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, أوروبا ,أستراليا, إلخ.

5. Which standards do you comply with when you produce the electrical wires and cables ?

We are able to produce electrical wires and cables based on GB, JB, IEC, BS, من, ASTM, JIS, NF, AS/NZS, CSA, إلخ. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

6. What is the min.order quantity ?

It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

7. What is the production capacity per week or per month ?

For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.

8. Do you supply the customers with installation service in foreign country ?We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.