UC3 Customized Smart Meter Three-Phase 90A 12VDC Magnetic Latching Relay
نموذج رقم.
IM901T
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
بحجم
Miniature
اكتب
Electric Parameter Relay
اسم المنتج
90A 12VDC Magnetic Latching Relay for Smart Meter
الأعلى. Switching Current
90أ
الأعلى. Switching Voltage
250بطالة
Contact Arrangement
3A/3b
الجهد الاسمي
6~48VDC
Power Consumption
Single Coil:3.0دبليو, Dual Coil:6.0دبليو
الأعلى. Switching Power
22500 Va
Contact Material
Agsno2
Picking-up & Release Time
Less Than or Equal to 20ms
Ambient Temperature
-40~+70 Degree
علامة تجارية
IVY
حزمة النقل
Cartons/Pallet
تخصيص
98*40*35.7مم
أصل
تشجيانغ, الصين
رمز النظام المنسق
8536411000
وصف


Basic Datأ | البعد(مم) | 98*40*35.7 | |
وزن ( ز ) | / | ||
Contact Arrangement | 3A/3ب | ||
Contact Material | AgSnO2 | ||
Ambient Temperature | -40~+70º ج | ||
Ambient حumidity | 45%~90%RH | ||
Vibration | 10~55هرتز,1.5مم(DA) | ||
Specification Datأ | الجهد الاسمي | 6~48VDC | |
Power Consumption | Single Coil:3.0دبليو, Dual Coil:6.0دبليو | ||
الأعلى. Switching الجهد االكهربى | 250الخامسAC | ||
الأعلى. Switching Current | 90أ | ||
الأعلى. Switching قوة | 22500 الخامسأ | ||
Contact Resistance | <2 mΩ | ||
Insulation Resistance | 1000MΩ(العاصمة 500الخامس) | ||
Dielectric Strength | Across Open جontact | >2000VAC 1min | |
Coil to Contact | >4000VAC 1min | ||
Electrical Life | >10,000cycles | ||
Mechanical Life | >100,000cycles | ||
Picking-up & Release زمن | <=20آنسة | ||
Pulse Duration | / | ||
Functional Shock Resistance | 10جي | ||
Destructive Shock Resistance | 100جي |
Cautions of Latching Relay:
1.Suggestions of relay’s input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then”+ -” or “- +”are fine,
you can change it by one pulse.If double coil then it’s necessary to confirm “-+-” or “+-+”before leaving the our factory.
(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
2.Suggestions of relay’s output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
the installation.
(2)When the relay will be connected with screw or bolts to the relays’ terminals, plz make sure your connection is
fastened and prevent relay from damages or other safety problems due to temp. Rise..
(3)The sampling signal wires of products are limited, please do not pull or torque during installation.