UC3 Single Phase Motor Control 100A Power Latching Meter Relay
نموذج رقم.
IM-M1202
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
بحجم
Miniature
اكتب
Electric Parameter Relay
اسم المنتج
Mini Motor Control 100A Power Latching Relay
Contact Material
Agsno2
Rated Load
100أ, 250بطالة
Coil Voltage
12VDC
اللون
أسود
علامة تجارية
IVY
حزمة النقل
Cartons/Pallet
تخصيص
29*23.5*16مم
أصل
تشجيانغ, الصين
رمز النظام المنسق
8536411000
وصف



Basic Datأ | Dimensions(مم) | 29×23.5×16 | |
وزن ( ز ) | ≈40g | ||
Contact Arrangement | 1A/1B | ||
Contact Material | AgSnO2 | ||
Ambient Temperature | –40~+75º ج | ||
Vibration | 10~50Hz,1.5مم | ||
Shock | 1000m/s²,(100ز) | ||
Specifications Datأ | Power Consumption | <3دبليو | |
Operating Voltage | 10.5-16الخامس | ||
الأعلى. Switching Current | 100أ | ||
سurge جurrent | 6000A/10ms | ||
Motor Resistance | 32(1±15%)Ω | ||
Contact Voltage | <60mV | ||
Contact Resistance | ≤1.0mΩ | ||
Dielectric Strength | Motor to جontact | >4000بطالة,50/60هرتز 1min | |
Across Open جontact | >2000بطالة,50/60هرتز 1min | ||
Electrical Life(120 cycles/H) | 10,000 (resistance 5 k + perceptual 5 k, co ϕ = 0.5) | ||
Mechanical Life(3600 cycles/H) | 100,000 | ||
Pulse Time | ≥60آنسة(Advise 60ms~100آنسة) | ||
Picking-up زمن | ≤60آنسة | ||
Release زمن | ≤60آنسة | ||
Insulation Resistance | >1000MΩ(500VDC) |
Cautions of Latching Relay:
1.Suggestions of relay’s input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then”+ -” or “- +”are fine,
you can change it by one pulse.If double coil then it’s necessary to confirm “-+-” or “+-+”before leaving the our factory.
(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
2.Suggestions of relay’s output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
the installation.
(2)When the relay will be connected with screw or bolts to the relays’ terminals, plz make sure your connection is
fastened and prevent relay from damages or other safety problems due to temp. Rise..
(3)The sampling signal wires of products are limited, please do not pull or torque during installation.