UC3 Single Phase Motor Control 100A Power Latching Meter Relay

نموذج رقم.
IM-M1202

Protective Characteristics
Sealed Relay

Action Principle
Electromagnetic Type

بحجم
Miniature

اكتب
Electric Parameter Relay

اسم المنتج
Mini Motor Control 100A Power Latching Relay

Contact Material
Agsno2

Rated Load
100أ, 250بطالة

Coil Voltage
12VDC

اللون
أسود

علامة تجارية
IVY

حزمة النقل
Cartons/Pallet

تخصيص
29*23.5*16مم

أصل
تشجيانغ, الصين

رمز النظام المنسق
8536411000

وصف


UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay

Basic DatأDimensions(مم)29×23.5×16
وزن ( ز )≈40g
Contact Arrangement1A/1B
Contact MaterialAgSnO2
Ambient Temperature40~+75º ج
Vibration10~50Hz,1.5مم
Shock1000m/s²,(100ز)
Specifications DatأPower Consumption<3دبليو
Operating Voltage10.5-16الخامس
الأعلى. Switching Current100أ
سurge جurrent6000A/10ms
Motor Resistance32(1±15%
Contact Voltage<60mV
Contact Resistance≤1.0
Dielectric StrengthMotor to جontact>4000بطالة,50/60هرتز 1min
Across Open جontact>2000بطالة,50/60هرتز 1min
Electrical Life(120 cycles/H)10,000
(resistance 5 k + perceptual 5 k, co ϕ = 0.5)
Mechanical Life(3600 cycles/H)100,000
Pulse Time60آنسة(Advise 60ms~100آنسة)
Picking-up زمن≤60آنسة
Release زمن≤60آنسة
Insulation Resistance>1000(500VDC)

UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
Cautions of Latching Relay:

1.Suggestions of relay’s input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then”+ -” or “- +”are fine,

you can change it by one pulse.If double coil then it’s necessary to confirm “-+-” or “+-+”before leaving the our factory.
(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
2.Suggestions of relay’s output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
the installation.
(2)When the relay will be connected with screw or bolts to the relaysterminals, plz make sure your connection is
fastened and prevent relay from damages or other safety problems due to temp. Rise..
(3)The sampling signal wires of products are limited, please do not pull or torque during installation.