This series includes:
نحاس (aluminum) core, PVC insulated and sheathed power cables
نحاس (aluminum) core, PVC insulated, PE sheathed power cables
نحاس (aluminum) core, PVC insulated, steel tape armoring PVC sheathed power cables
نحاس (aluminum) core, PVC insulated, steel tape armoring, PE sheathed power cables
نحاس (aluminum) core, PVC insulated, steel wire armoring, PVC sheathed power cables
نحاس (aluminum) core, PVC insulated, steel wire armoring, PE sheathed power cables
This series is mainly laid indoor, cable slot, direct burial, channel, mining well and water condition. This series has the following characteristics: The max. Rated temperature of the conductor is 70 degree. The max. Temperature of the conductor of the cables cannot exceed 160 degrees.
The cables can be laid without the limit of fall with enough mechanical pull, but the single core cable cannot be laid in iron tube or cannot be fixed by circled iron tools around the cables.
The laying temperature of cables should not be lower than 0 degree, When the ambient temperature is under 0 degree, the cables should be heated up to 0 degree higher with certain methods.
Rated voltage: 0.6/1kV, 3.6/6kV* Number of cores: 1-6
Standarded: IEC, BS, من, غيغابايت, any standard
Remarks: Including products for flame retardant, fire resistant and termite-proof
Packing: Wooden drum, steel wooden drum
1)600/1000الخامس, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable | ||||||||||||
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Unarmoured | Armoured | ||||||||
Thickness of Sheath | Overall Dia. | Approx. الوزن الصافي | Thickness of Bedding | Thickness of Al Tape | Thickness of Sheath | Overall Dia. | Approx. الوزن الصافي | |||||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||||
مم 2 | – | مم | مم | مم | kg/km | kg/km | مم | مم | مم | مم | kg/km | kg/km |
1.5 | 1 | 0.8 | 1.4 | 5.8 | – | 51 | – | – | – | – | – | – |
2.5 | 1 | 0.8 | 1.4 | 6.2 | – | 64 | – | – | – | – | – | – |
4 | 1 | 1 | 1.4 | 7.1 | – | 88 | – | – | – | – | – | – |
6 | 7 | 1 | 1.4 | 7.8 | 78 | 114 | – | – | – | – | – | – |
10 | 7 | 1 | 1.4 | 8.6 | 96 | 159 | 1 | 0.5 | 1.8 | 13.4 | 234 | 295 |
16 | 7 | 1 | 1.4 | 9.6 | 123 | 222 | 1 | 0.5 | 1.8 | 14.4 | 274 | 370 |
25 | 7 | 1.2 | 1.4 | 11.2 | 172 | 328 | 1 | 0.5 | 1.8 | 16 | 344 | 496 |
35 | 7 | 1.2 | 1.4 | 12.2 | 209 | 428 | 1 | 0.5 | 1.8 | 17 | 393 | 606 |
50 | 19 | 1.4 | 1.4 | 13.9 | 271 | 565 | 1 | 0.5 | 1.8 | 18.7 | 478 | 764 |
70 | 19 | 1.4 | 1.5 | 15.9 | 356 | 818 | 1 | 0.5 | 1.8 | 20.5 | 582 | 1020 |
95 | 19 | 1.6 | 1.5 | 18 | 471 | 1041 | 1 | 0.5 | 1.8 | 22.6 | 717 | 1291 |
120 | 37 | 1.6 | 1.6 | 19.6 | 563 | 1307 | 1 | 0.5 | 1.8 | 24 | 822 | 1545 |
150 | 37 | 1.8 | 1.6 | 21.3 | 684 | 1592 | 1 | 0.5 | 1.8 | 25.4 | 952 | 1857 |
185 | 37 | 2 | 1.7 | 23.9 | 840 | 1985 | 1 | 0.5 | 1.8 | 27.9 | 1136 | 2236 |
240 | 61 | 2.2 | 1.8 | 27 | 1071 | 2533 | 1 | 0.5 | 1.9 | 31 | 1404 | 2877 |
300 | 61 | 2.4 | 1.9 | 29.6 | 1317 | 3162 | 1.2 | 0.5 | 2.1 | 34.3 | 1722 | 3551 |
400 | 61 | 2.6 | 2 | 33.2 | 1666 | 4120 | 1.2 | 0.5 | 2.2 | 37.6 | 2114 | 4488 |
500 | 61 | 2.8 | 2.2 | 37.5 | 2089 | 5163 | 1.2 | 0.5 | 2.3 | 42.1 | 2592 | 5683 |
630 | 61 | 2.8 | 2.3 | 41.2 | 2581 | 6447 | 1.4 | 0.5 | 2.4 | 46.3 | 3184 | 7060 |
2)600/1000الخامس, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable | ||||||||||||
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. الوزن الصافي | ||||||
Al Conductor | Cu Conductor | |||||||||||
– | مم 2 | – | مم | مم | مم | kg/km | kg/km | |||||
Three Cores | 3×35 | 16 | 1.2 | 1.8 | 21.9 | 601 | 1280 | |||||
3×50 | 18 | 1.4 | 1.8 | 26.5 | 829 | 1732 | ||||||
3×70 | 18 | 1.4 | 1.9 | 29.2 | 1067 | 2367 | ||||||
3×95 | 36 | 1.6 | 2 | 32.9 | 1409 | 2317 | ||||||
3×120 | 36 | 1.6 | 2.1 | 36.2 | 1705 | 3983 | ||||||
3×150 | 36 | 1.8 | 2.2 | 38.8 | 2045 | 4872 | ||||||
3×185 | 36 | 2 | 2.4 | 44.8 | 2596 | 6077 | ||||||
3×240 | 60 | 2.2 | 2.6 | 51.5 | 3353 | 7953 | ||||||
3×300 | 60 | 2.4 | 2.7 | 54.9 | 6069 | 9820 | ||||||
Four Cores with Reduced Neutral | 3×35+16 | 716 | 1.2-1 | 1.8 | 25.5 | 764 | 1107 | |||||
3×50+25 | 18-16 | 1.4-1.2 | 1.9 | 28.7 | 982 | 1410 | ||||||
3×70+35 | 18-16 | 1.4-1.2 | 2 | 32 | 1278 | 1733 | ||||||
3×95+50 | 36-18 | 1.6-1.4 | 2.2 | 37.8 | 1711 | 2656 | ||||||
3×120+70 | 36-18 | 1.6-1.4 | 2.3 | 40.5 | 2065 | 3137 | ||||||
3×150+70 | 36-18 | 1.8-1.4 | 2.4 | 44.8 | 2480 | 3660 | ||||||
3×185+95 | 36-36 | 2-1.6 | 2.6 | 49.7 | 3086 | 4345 | ||||||
3×240+120 | 60-36 | 2.2-1.6 | 2.8 | 56 | 3894 | 5441 | ||||||
3×300+150 | 60-36 | 1.4-1.8 | 2.9 | 60.3 | 4834 | 6494 | ||||||
Four Cores | 4×25 | 16 | 1.2 | 1.8 | 22.5 | 644 | 1286 | |||||
4×35 | 16 | 1.2 | 1.8 | 24.6 | 799 | 1696 | ||||||
4×50 | 18 | 1.4 | 1.8 | 28.6 | 1071 | 2275 | ||||||
4×70 | 18 | 1.4 | 2 | 31.6 | 1387 | 3120 | ||||||
4×95 | 36 | 1.6 | 2.1 | 35.9 | 1850 | 4262 | ||||||
4×120 | 36 | 1.6 | 2.2 | 38.8 | 2209 | 5247 | ||||||
4×150 | 36 | 1.8 | 2.3 | 43.1 | 2714 | 6483 | ||||||
4×185 | 36 | 2 | 2.5 | 48.7 | 3403 | 8045 | ||||||
4×240 | 60 | 2.2 | 2.7 | 53.6 | 4290 | 10422 | ||||||
4×300 | 60 | 2.4 | 2.9 | 58.8 | 5302 | 12969 | ||||||
3)600/1000الخامس, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable | ||||||||||||
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. الوزن الصافي | ||||||
Al Conductor | Cu Conductor | |||||||||||
– | مم 2 | – | مم | مم | مم | kg/km | kg/km | |||||
Three Cores | 3×10 | 7 | 1 | 1.8 | 16.6 | 281 | 465 | |||||
3×16 | 7 | 1 | 1.8 | 18.7 | 387 | 679 | ||||||
3×25 | 7 | 1.2 | 1.8 | 22.2 | 536 | 996 | ||||||
3×35 | 7 | 1.2 | 1.8 | 24.4 | 665 | 1311 | ||||||
3×50 | 19 | 1.4 | 1.9 | 28.1 | 863 | 1729 | ||||||
3×70 | 19 | 1.4 | 2 | 32.3 | 1153 | 2480 | ||||||
3×95 | 19 | 1.6 | 2.1 | 37.1 | 1563 | 3301 | ||||||
3×120 | 37 | 1.6 | 2.3 | 40.4 | 1850 | 4040 | ||||||
3×150 | 37 | 1.8 | 2.4 | 43.9 | 2258 | 5000 | ||||||
3×185 | 37 | 2 | 2.5 | 49.2 | 2819 | 6151 | ||||||
3×240 | 61 | 2.2 | 2.8 | 55.9 | 3577 | 8040 | ||||||
3×300 | 61 | 2.4 | 3 | 62.1 | 4413 | 9955 | ||||||
3×400 | 61 | 2.6 | 3.2 | 69.3 | 5512 | 12705 | ||||||
Four Cores | 4×10 | 7 | 1 | 1.8 | 18.1 | 343 | 589 | |||||
4×16 | 7 | 1 | 1.8 | 20.5 | 487 | 874 | ||||||
4×25 | 7 | 1.2 | 1.8 | 24.3 | 677 | 1291 | ||||||
4×35 | 7 | 1.2 | 1.8 | 26.8 | 821 | 1681 | ||||||
4×50 | 19 | 1.4 | 2 | 31.2 | 1118 | 2273 | ||||||
4×70 | 19 | 1.4 | 2.1 | 35.8 | 1494 | 3264 | ||||||
4×95 | 19 | 1.6 | 2.3 | 41.2 | 1993 | 4312 | ||||||
4×120 | 37 | 1.6 | 2.4 | 44.8 | 2370 | 5291 | ||||||
4×150 | 37 | 1.8 | 2.5 | 48.7 | 2959 | 6615 | ||||||
4×185 | 37 | 2 | 2.7 | 54.7 | 3601 | 8044 | ||||||
4×240 | 61 | 2.2 | 3 | 62.1 | 4596 | 10547 | ||||||
4×300 | 61 | 2.4 | 3.2 | 69.1 | 5614 | 13004 |
ورشة عمل
QC&TESTING MACHINE
CERTIFICATE
Shipment
CUSTOMER VISIT
التعليمات
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,الصين
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) الأسلاك ;
4) PVC Insulated and Sheathed (Armoured) سلك الطاقة;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) سلك الطاقة;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, هذه, ISO9001-2000, اس جي اس
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, أوروبا ,أستراليا, إلخ.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, من, ASTM, JIS, NF, AS/NZS, CSA, إلخ. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.