Yjv Yjv22 Yjv32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage
Modell Nr.
low voltage cable
Wire Core Material
Bare Copper Wire
Zertifizierung
ISO, CCC, CE, RoHS, UL, VDE
Modell
VV, Yjv…
Marke
Chang Qing Teng
Produktname
Low Voltage Cable/ PVC Cable/ XLPE Cable/ Armoured
Number of Cores
Single/2/3/4/5/6/7/8/10/16 Core…
Cross Section Area/Measure
3.5/4/6/10/16/25/35/50/70/95/120/150/185/240/300/4
Standard
IEC 60502-1, BS 7870-6, BS 6622, BS 7835, GB 5023-
Dirigent
Stranded/Solid/Flexible Copper/Aluminum Conductor
Isolierung
XLPE/PVC/PE/PUR
Aplication
Electric, House Wire, Building Wire…
Shield
Copper Wire Screen(Cws), Aluminium Wire Screen(Aws
Armoured
Steel Tape Armoured (Sta) or Steel Wire Armoured (
Warenzeichen
Luxing
Transportpaket
Non-Fumigation Wooden Drum, Iron-Wooden Drum.
Spezifikation
350x160x270,800x350x550,1000x500x600,1200x500x900.
Herkunft
Shandong
HS-Code
8544492100
Beschreibung
YJV YJV22 YJV32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage
1.Applications
-These cables are used for electricity supply in low voltage installation system.
-They are suitable for installation in indoors and outdoors,in cable ducts, underground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.
2.Konstruktion
–Dirigenten
The conductors shall be either of Class 1 or Class 2 of plain accordance with IEC 60228.
–Isolierung
PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.
–Assembly / Inner Covering
The inner coverings may be extruded or lapped.
–Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
–Outer Sheath
Outer sheath shall be of extruded PVC as per IEC 60502-1, Polyethylene, Halogen free compound.
Polychloroprene, chlorosulfonated polyethylene or similar polymers.
–Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
3.Parameter
Single core(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
1×4 | 2.3 | 1 | 1.4 | 7.1 | ||
1×6 | 2.8 | 1 | 1.4 | 7.6 | ||
1×10 | 3.6 | 1 | 1.4 | 8.4 | ||
1×16 | 4.5 | 1 | 1.4 | 9.3 | ||
1×25 | 5.6 | 1.2 | 1.4 | 10.8 | ||
1×35 | 6.7 | 1.2 | 1.4 | 11.9 | ||
1×50 | 8 | 1.4 | 1.4 | 13.6 | ||
1×70 | 9.4 | 1.4 | 1.4 | 15.1 | ||
1×95 | 11 | 1.6 | 1.5 | 17.2 | ||
1×120 | 12.4 | 1.6 | 1.5 | 18.7 | ||
1×150 | 13.8 | 1.8 | 1.6 | 20.6 | ||
1×185 | 15.3 | 2 | 1.7 | 22.7 | ||
1×240 | 17.5 | 2.2 | 1.8 | 25.4 | ||
1×300 | 19.5 | 2.4 | 1.9 | 28.0 | ||
1×400 | 22.6 | 2.6 | 2.0 | 31.7 | ||
1×500 | 25.2 | 2.8 | 2.1 | 35.0 | ||
1×630 | 28.3 | 2.8 | 2.2 | 38.3 |
Two cores(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
2×1.5 | 1.4 | 0.8 | 1.8 | 9.6 | ||
2×2.5 | 1.8 | 0.8 | 1.8 | 10.4 | ||
2×4 | 2.3 | 1 | 1.8 | 12.2 | ||
2×6 | 2.8 | 1 | 1.8 | 13.2 | ||
2×10 | 3.6 | 1 | 1.8 | 14.8 | ||
2×16 | 4.5 | 1 | 1.8 | 16.6 | ||
2×25 | 5.6 | 1.2 | 1.8 | 19.6 | ||
2×35 | 6.7 | 1.2 | 1.8 | 21.8 | ||
2×50 | 8 | 1.4 | 1.8 | 25.2 | ||
2×70 | 9.4 | 1.4 | 1.9 | 28.1 | ||
2×95 | 11 | 1.6 | 2.0 | 32.4 | ||
2×120 | 12.4 | 1.6 | 2.1 | 35.4 | ||
2×150 | 13.8 | 1.8 | 2.2 | 39.2 | ||
2×185 | 15.3 | 2 | 2.4 | 43.3 | ||
2×240 | 17.5 | 2.2 | 2.5 | 48.9 | ||
2×300 | 19.5 | 2.4 | 2.7 | 54.0 | ||
2×400 | 22.6 | 2.6 | 2.9 | 61.5 |
Three cores(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
3×1.5 | 1.4 | 0.8 | 1.8 | 10.1 | ||
3×2.5 | 1.8 | 0.8 | 1.8 | 10.9 | ||
3×4 | 2.3 | 1 | 1.8 | 12.9 | ||
3×6 | 2.8 | 1 | 1.8 | 13.9 | ||
3×10 | 3.6 | 1 | 1.8 | 15.7 | ||
3×16 | 4.5 | 1 | 1.8 | 17.6 | ||
3×25 | 5.6 | 1.2 | 1.8 | 20.8 | ||
3×35 | 6.7 | 1.2 | 1.8 | 23.2 | ||
3×50 | 8 | 1.4 | 1.8 | 26.9 | ||
3×70 | 9.4 | 1.4 | 1.9 | 30.1 | ||
3×95 | 11 | 1.6 | 2.1 | 34.7 | ||
3×120 | 12.4 | 1.6 | 2.2 | 38.0 | ||
3×150 | 13.8 | 1.8 | 2.3 | 42.1 | ||
3×185 | 15.3 | 2 | 2.5 | 46.5 | ||
3×240 | 17.5 | 2.2 | 2.7 | 52.5 | ||
3×300 | 19.5 | 2.4 | 2.8 | 58.0 | ||
3×400 | 22.6 | 2.6 | 3.1 | 66.1 |
Three cores+1(unarmoured) | ||||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||||
mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm | ||
3x 16/10 | 4.5 | 3.6 | 1 | 1 | 1.8 | 19.0 | ||
3x 25/16 | 5.6 | 4.5 | 1.2 | 1 | 1.8 | 22.6 | ||
3x 35/16 | 6.7 | 4.5 | 1.2 | 1 | 1.8 | 25.3 | ||
3x 50/25 | 8.0 | 5.6 | 1.4 | 1.2 | 1.9 | 29.6 | ||
3x 70/35 | 9.4 | 6.7 | 1.4 | 1.2 | 2.0 | 33.2 | ||
3x 95/50 | 11.0 | 8.0 | 1.6 | 1.4 | 2.2 | 38.4 | ||
3×120/70 | 12.4 | 9.4 | 1.6 | 1.4 | 2.3 | 42.0 | ||
3×150/70 | 13.8 | 9.4 | 1.8 | 1.4 | 2.5 | 46.6 | ||
3×185/95 | 15.3 | 11.0 | 2 | 1.6 | 2.6 | 51.6 | ||
3×240/120 | 17.5 | 12.4 | 2.2 | 1.6 | 2.9 | 58.3 | ||
3×300/150 | 19.5 | 13.8 | 2.4 | 1.8 | 3.1 | 64.5 | ||
3×400/185 | 22.6 | 15.3 | 2.6 | 2 | 3.3 | 73 |
Four cores(unarmored) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
4×1.5 | 1.4 | 0.8 | 1.8 | 10.8 | ||
4×2.5 | 1.8 | 0.8 | 1.8 | 11.8 | ||
4×4 | 2.3 | 1 | 1.8 | 14.0 | ||
4×6 | 2.8 | 1 | 1.8 | 15.2 | ||
4×10 | 3.6 | 1 | 1.8 | 17.1 | ||
4×16 | 4.5 | 1 | 1.8 | 19.3 | ||
4×25 | 5.6 | 1.2 | 1.8 | 22.9 | ||
4×35 | 6.7 | 1.2 | 1.8 | 25.6 | ||
4×50 | 8 | 1.4 | 1.9 | 29.9 | ||
4×70 | 9.4 | 1.4 | 2.0 | 33.5 | ||
4×95 | 11 | 1.6 | 2.2 | 38.7 | ||
4×120 | 12.4 | 1.6 | 2.3 | 42.3 | ||
4×150 | 13.8 | 1.8 | 2.5 | 46.9 | ||
4×185 | 15.3 | 2 | 2.6 | 51.9 | ||
4×240 | 17.5 | 2.2 | 2.9 | 58.6 | ||
4×300 | 19.5 | 2.4 | 3.1 | 64.8 | ||
4×400 | 22.6 | 2.6 | 3.3 | 73.8 |
Multi-cores(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
5×1.5 | 1.4 | 0.8 | 1.8 | 11.7 | ||
7×1.5 | 1.4 | 0.8 | 1.8 | 12.6 | ||
10×1.5 | 1.4 | 0.8 | 1.8 | 15.6 | ||
12×1.5 | 1.4 | 0.8 | 1.8 | 16.1 | ||
14×1.5 | 1.4 | 0.8 | 1.8 | 16.8 | ||
19×1.5 | 1.4 | 0.8 | 1.8 | 18.6 | ||
21×1.5 | 1.4 | 0.8 | 1.8 | 19.5 | ||
24×1.5 | 1.4 | 0.8 | 1.8 | 21.6 | ||
30×1.5 | 1.4 | 0.8 | 1.8 | 22.8 | ||
40×1.5 | 1.4 | 0.8 | 1.8 | 27.7 | ||
48×1.5 | 1.4 | 0.8 | 1.9 | 28.2 | ||
61×1.5 | 1.4 | 0.8 | 1.9 | 30.9 | ||
5×2.5 | 1.8 | 0.8 | 1.8 | 12.8 | ||
7×2.5 | 1.8 | 0.8 | 1.8 | 13.8 | ||
10×2.5 | 1.8 | 0.8 | 1.8 | 17.2 | ||
12×2.5 | 1.8 | 0.8 | 1.8 | 17.7 | ||
14×2.5 | 1.8 | 0.8 | 1.8 | 18.6 | ||
19×2.5 | 1.8 | 0.8 | 1.8 | 20.6 | ||
21×2.5 | 1.8 | 0.8 | 1.8 | 21.6 | ||
24×2.5 | 1.8 | 0.8 | 1.8 | 24.0 | ||
30×2.5 | 1.8 | 0.8 | 1.8 | 25.4 | ||
40×2.5 | 1.8 | 0.8 | 2.0 | 31.1 | ||
48×2.5 | 1.8 | 0.8 | 2.0 | 31.7 | ||
61×2.5 | 1.8 | 0.8 | 2.1 | 34.7 |
4.Kontaktiere uns
If you need low voltage cable, medium voltage cable, control cable, rubber cable,
ABC cable, ACSR, underground cable, armoured cable, XLPE cable, PVC cable,