IEC 60502 600/1000V PVC / XLPE Insulated Power Cable

Modèle NON.
power cable

Wire Core Material
Red Copper Wire

Certificat
ISO, CCC, SGS

Modèle
YJV

Marque
Hongda

Standard
IEC 60502

Non. of Cores
1 Core, 2 Cores, 3 Cores, 4 Cores, 5 Cores

Armour
Aluminum/Galvanized Steel/Steel Wires

Marque déposée
Hongda, accept OEM

Forfait transport
Acier & Wooden Drum or Customer Requirement

spécification
10 sqmm to 240 sqmm

Origine
Chine

Code SH
8544492100

La description

600/1000V, XLPE Insulated Cables according to IEC 60502-1

Application:
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

Construction:

IEC 60502 600/1000V PVC / XLPE Insulated Power Cable
Conductor:annealed copper or of plain aluminium or aluminium alloy
Insulation:XLPE / PVC material
Armour:
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
Sheath:PVC compound
sheath colour:black

Technical data:

Temperature range:
during installation:-5 °C up to +50 °C
fixed installed:-30 °C up to +70 °C
at short circuit of max. 5 s:Jusqu'à 160 °C
Nominal voltage:Uο/U = 0,6/1 kV
Test voltage:4 kV
Max. operating voltage in three-phase systems:1,2 kV
Maximal tensile strength:50 N/mm²
Behaviour in fire:IEC 60332-1
Minimal inner bending radius:
single core:15ré
multi core:12ré


Dimensions:

Single core(unarmoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2millimètremillimètremillimètremillimètre
1×1.51.40.71.45.6
1×2.51.80.71.46.0
1×42.30.71.46.5
1×62.80.71.47.0
1×103.60.71.47.8
1×164.50.71.48.7
1×255.60.91.410.2
1×356.70.91.411.3
1×508.011.412.8
1×709.41.11.414.4
1×9511.01.11.516.1
1×12012.41.21.517.8
1×15013.81.41.619.8
1×18515.31.61.621.8
1×24017.51.71.724.4
1×30019.51.81.826.7
1×40022.621.930.5
1×50025.22.22.033.7
1×63028.32.42.237.4
1×80031.92.62.341.7
1×100035.72.82.446.2

Two cores(unarmoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2millimètremillimètremillimètremillimètre
2×1.51.40.71.89.2
2×2.51.80.71.810.0
2×42.30.71.811.0
2×62.80.71.812.0
2×103.60.71.813.6
2×164.50.71.815.4
2×255.60.91.818.4
2×356.70.91.820.6
2×508.011.823.6
2×709.41.11.826.8
2×9511.01.11.930.2
2×12012.41.22.033.7
2×15013.81.42.237.5
2×18515.31.62.341.6
2×24017.51.72.546.7
2×30019.51.82.651.4
2×40022.622.958.9

Three cores(unarmoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2millimètremillimètremillimètremillimètre
3×1.51.40.71.89.6
3×2.51.80.71.810.5
3×42.30.71.811.6
3×62.80.71.812.6
3×103.60.71.814.4
3×164.50.71.816.3
3×255.60.91.819.5
3×356.70.91.821.9
3×508.011.825.1
3×709.41.11.928.7
3×9511.01.12.032.4
3×12012.41.22.136.1
3×15013.81.42.340.3
3×18515.31.62.444.6
3×24017.51.72.650.2
3×30019.51.82.755.2
3×40022.623.063.3

Three cores+1(unarmoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2(3)millimètre(1)millimètre(3)millimètre(1)millimètremillimètremillimètre
3X 16/104.53.60.70.71.817.5
3X 25/165.64.50.90.71.821.2
3X 35/166.74.50.90.71.823.8
3X 50/2585.610.91.827.5
3X 70/359.46.71.10.92.031.7
3X 95/501181.112.135.8
3×120/7012.49.41.21.12.339.9
3×150/7013.89.41.41.12.444.6
3×185/9515.3111.61.12.649.5
3×240/12017.512.41.71.22.855.7
3×300/15019.513.81.81.43.061.4
3×400/18522.615.321.63.270.4

Four cores(unarmoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2millimètremillimètremillimètremillimètre
4×1.51.40.71.810.4
4×2.51.80.71.811.3
4×42.30.71.812.5
4×62.80.71.813.7
4×103.60.71.815.7
4×164.50.71.817.8
4×255.60.91.821.5
4×356.70.91.824.1
4×508.011.827.8
4×709.41.12.032.0
4×9511.01.12.136.1
4×12012.41.22.340.2
4×15013.81.42.444.9
4×18515.31.62.649.8
4×24017.51.72.856.0
4×30019.51.83.061.7
4×40022.623.270.7

Multi-cores(unarmoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2millimètremillimètremillimètremillimètre
5×1.51.40.71.811.2
7×1.51.40.71.812.0
10×1.51.40.71.814.8
12×1.51.40.71.815.2
14×1.51.40.71.816.0
19×1.51.40.71.817.6
21×1.51.40.71.818.4
24×1.51.40.71.820.4
30×1.51.40.71.821.6
40×1.51.40.71.826.0
48×1.51.40.71.826.4
61×1.51.40.71.929.0
5×2.51.80.71.812.2
7×2.51.80.71.813.2
10×2.51.80.71.816.4
12×2.51.80.71.816.9
14×2.51.80.71.817.7
19×2.51.80.71.819.6
21×2.51.80.71.820.6
24×2.51.80.71.822.8
30×2.51.80.71.824.1
40×2.51.80.71.929.4
48×2.51.80.71.929.9
61×2.51.80.72.032.8

*) Emballage: CUT = cable in different lengths on drum or reel, possible cutting at required length.

For more information and inquiry, pls contact me without any hesitation.