Thhn Thwn Standard Copper PVC Nylon Building Electric Conductor 600volts, 90º C Dry Wet Wire
Modèle NON.
THHN
Forme du matériau
Fil rond
Domaine d'application
Building
Certificat
ISO 9001, CE, CCC
Marque
Jinshui
Marque déposée
JINSHUI
Forfait transport
Roll
Origine
Zhengzhou Henan
Code SH
4107961636
La description
THHN/THWN Copper Conductor 600Volts,90ºC Dry or Wet
1.Standard
U183, UL1581
2.Applications
THHN/THWN Conductors are primarily used in conduit for services,feeder and branch circuits in commercial or industrial applications as specified in the National Electrical Code. For the type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90ºC. As for the type THWN,conductor is suitable in wet or dry locations at temperatures not to exceed 90ºC in dry locations or 75ºC in wet locations or not to wxceed 75ºC when exposed to oil or coolant. Conductor temperatures are not to exceed 105ºC in dry locations when rated AWM, which is used as appliance wiring material. Voltage rating for all applications in 600 volts.
3.Construction
Conductor:cuivre,aliminum,aluminum alloy, CCA
Insulation:flame retardant PVC(polyvinyl chloride).
Jacket:tough polyamide nylon,It is also resistant to oil ,gasoline and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90ºC dry only.
1:THHN:It indicates a single or stranded conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90ºC dry only.
2:It indicates a single or stranded conductor having flame-retardant,moisture and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent. The Wire is rated 75ºC wet or 90 ºC dry.
4.Taper&spécification
Type THHN/MTW/THWN-2/T90 Copper Conductor 600V
1.Standard
U183, UL1581
2.Applications
THHN/THWN Conductors are primarily used in conduit for services,feeder and branch circuits in commercial or industrial applications as specified in the National Electrical Code. For the type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90ºC. As for the type THWN,conductor is suitable in wet or dry locations at temperatures not to exceed 90ºC in dry locations or 75ºC in wet locations or not to wxceed 75ºC when exposed to oil or coolant. Conductor temperatures are not to exceed 105ºC in dry locations when rated AWM, which is used as appliance wiring material. Voltage rating for all applications in 600 volts.
3.Construction
Conductor:cuivre,aliminum,aluminum alloy, CCA
Insulation:flame retardant PVC(polyvinyl chloride).
Jacket:tough polyamide nylon,It is also resistant to oil ,gasoline and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90ºC dry only.
1:THHN:It indicates a single or stranded conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90ºC dry only.
2:It indicates a single or stranded conductor having flame-retardant,moisture and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent. The Wire is rated 75ºC wet or 90 ºC dry.
4.Taper&spécification
Type THHN/MTW/THWN-2/T90 Copper Conductor 600V