UC3 Customized Smart Meter Three-Phase 90A 12VDC Magnetic Latching Relay
Modèle NON.
IM901T
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
Taille
Miniature
Taper
Electric Parameter Relay
Nom du produit
90A 12VDC Magnetic Latching Relay for Smart Meter
Max. Switching Current
90UNE
Max. Switching Voltage
250VCA
Contact Arrangement
3A/3b
Nominal Voltage
6~48VDC
Consommation d'énergie
Single Coil:3.0O, Dual Coil:6.0O
Max. Switching Power
22500 Va
Contact Material
Agsno2
Picking-up & Release Time
Less Than or Equal to 20ms
Température ambiante
-40~+70 Degree
Marque déposée
IVY
Forfait transport
Cartons/Pallet
spécification
98*40*35.7millimètre
Origine
Zhejiang, Chine
Code SH
8536411000
La description


Basic Datun | Dimension(millimètre) | 98*40*35.7 | |
Masse ( g ) | / | ||
Contact Arrangement | 3A/3B | ||
Contact Material | AgSnO2 | ||
Température ambiante | -40~+70°C | ||
Ambient Humidity | 45%~90%RH | ||
Vibration | 10~55Hz,1.5millimètre(DA) | ||
Specification Datun | Nominal Voltage | 6~48VDC | |
Consommation d'énergie | Single Coil:3.0O, Dual Coil:6.0O | ||
Max. Switching Tension | 250VAC | ||
Max. Switching Current | 90UNE | ||
Max. Switching Pouvoir | 22500 VUNE | ||
Contact Resistance | <2 mΩ | ||
Insulation Resistance | 1000MΩ(CC 500V) | ||
Dielectric Strength | Across Open Contact | >2000VAC 1min | |
Coil to Contact | >4000VAC 1min | ||
Electrical Life | >10,000cycles | ||
Mechanical Life | >100,000cycles | ||
Picking-up & Release Time | <=20ms | ||
Pulse Duration | / | ||
Functional Shock Resistance | 10g | ||
Destructive Shock Resistance | 100g |
Cautions of Latching Relay:
1.Suggestions of relay’s input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then”+ -” ou “- +”are fine,
you can change it by one pulse.If double coil then it’s necessary to confirm “-+-” ou “+-+”before leaving the our factory.
(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
2.Suggestions of relay’s output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
the installation.
(2)When the relay will be connected with screw or bolts to the relays’ terminals, plz make sure your connection is
fastened and prevent relay from damages or other safety problems due to temp. Rise..
(3)The sampling signal wires of products are limited, please do not pull or torque during installation.