UC3 Single Phase Motor Control 100A Power Latching Meter Relay
Modèle NON.
IM-M1202
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
Taille
Miniature
Taper
Electric Parameter Relay
Nom du produit
Mini Motor Control 100A Power Latching Relay
Contact Material
Agsno2
Rated Load
100UNE, 250VCA
Coil Voltage
12VCC
Couleur
Le noir
Marque déposée
IVY
Forfait transport
Cartons/Pallet
spécification
29*23.5*16millimètre
Origine
Zhejiang, Chine
Code SH
8536411000
La description



Basic Datun | Dimensions(millimètre) | 29×23.5×16 | |
Masse ( g ) | ≈40g | ||
Contact Arrangement | 1A/1B | ||
Contact Material | AgSnO2 | ||
Température ambiante | –40~+75°C | ||
Vibration | 10~50Hz,1.5millimètre | ||
Shock | 1000m/s²,(100g) | ||
Specifications Datun | Consommation d'énergie | <3O | |
Operating Voltage | 10.5-16V | ||
Max. Switching Current | 100UNE | ||
Surge Current | 6000A/10ms | ||
Motor Resistance | 32(1±15%)Ω | ||
Contact Voltage | <60mV | ||
Contact Resistance | ≤1.0mΩ | ||
Dielectric Strength | Motor to Contact | >4000VCA,50/60Hz 1min | |
Across Open Contact | >2000VCA,50/60Hz 1min | ||
Electrical Life(120 cycles/H) | 10,000 (resistance 5 k + perceptual 5 k, co ϕ = 0.5) | ||
Mechanical Life(3600 cycles/H) | 100,000 | ||
Pulse Time | ≥60ms(Advise 60ms~100ms) | ||
Picking-up Time | ≤60ms | ||
Release Time | ≤60ms | ||
Insulation Resistance | >1000MΩ(500VCC) |
Cautions of Latching Relay:
1.Suggestions of relay’s input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then”+ -” ou “- +”are fine,
you can change it by one pulse.If double coil then it’s necessary to confirm “-+-” ou “+-+”before leaving the our factory.
(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
2.Suggestions of relay’s output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
the installation.
(2)When the relay will be connected with screw or bolts to the relays’ terminals, plz make sure your connection is
fastened and prevent relay from damages or other safety problems due to temp. Rise..
(3)The sampling signal wires of products are limited, please do not pull or torque during installation.