UTP CAT6 Cable Ethernet Network Cable RJ45 Patch Cord LAN Cable
La description
UTP CAT6 cable Ethernet Network Cable RJ45 Patch Cord LAN cable
Cat-6: This cable is defined in TIA/EIA-568-B provides a significant improvement in performance over Cat5 and Cat 5e.
During manufacture Cat 6 cables are more tightly wound than either Cat 5 or Cat 5e and they often have an outer foil or braided shielding.
The shielding protects the twisted pairs of wires inside the Ethernet cable, helping to prevent crosstalk and noise interference.
Cat-6 cables can technically support speeds up to 10 Gbps, but cat6 ethernet cable can only do so for up to 55 metres.
NOTE: 250-500Mhz/10 Gbps /100m.
Construction | ||||||||
Conductor: | 23 AWG Solid Bare Copper/CCA | |||||||
Pairs: | 4 Pairs | |||||||
Insulation: | 1.02 mm HDPE | |||||||
Insulation Colors: | Blue-White/Blue,Orange-White/Orange | |||||||
Green-White/Green,Brown-White/Brown | ||||||||
Filler: | Cross Filler | |||||||
Rip Cord: | Cotton | |||||||
Out Jacket: | 6.4±0.2 mm PVC CM | |||||||
Electrical Characteristics | ||||||||
Impedance | 1 – 250MHz 100±15 Ohms | |||||||
Insulation Resistance | >5000MΩ*KM | |||||||
Dielectric strength | DC 2500V 2S | |||||||
Max.Conductor DC | 8.4 Ohms/100m | |||||||
Res. unbalance (%) | Max. 2.5 | |||||||
Pair to Ground | 330 pF/100m | |||||||
Transfer Impendance | Max 10 mOhms/m @100Mhz | |||||||
Installation temp. | -30 – 50°C | |||||||
Operation temp. | -20 – 75°C | |||||||
Cross Section | ||||||||
| ||||||||
Application | ||||||||
• Meets or exceeds requirements of ANSI/TIA-568-C.2 Category 6 et | ||||||||
• Meets or exceeds requirements of ANSI/TIA-568-C.2 and IEC 61156-5 | ||||||||
• Third party tested to comply with ANSI/TIA-568-C.2. | ||||||||
• Meets requirements of IEEE 802.3af and IEEE 802.3at for PoE applications. | ||||||||
• Descending length cable markings enable easy identification of remaining cable | ||||||||
• Color Availability: Additional cable colors available. | ||||||||
Performance Characteristics | ||||||||
Frequency | RL (Min.) | Insertion Loss(Max.) | Propagation Delay (Max.) | Delay Skew(Max.) | NEXT (Min.) | PSNEXT (Min.) | ELNEXT (Min.) | PSELNEXT (Min.) |
MHz | dB | dB/100m | ns/100m | ns/100m | dB | dB | dB/100m | dB/100m |
1 | 20.0 | 2.0 | 570.0 | 45.0 | 74.0 | 72.0 | 67.8 | 64.8 |
4 | 23.0 | 3.8 | 552.0 | 45.0 | 65.0 | 63.0 | 55.7 | 52.7 |
10 | 25.0 | 6.0 | 545.0 | 45.0 | 59.0 | 57.0 | 47.8 | 44.8 |
16 | 25.0 | 7.6 | 543.0 | 45.0 | 56.0 | 54.0 | 43.7 | 40.7 |
20 | 25.0 | 8.5 | 542.0 | 45.0 | 55.0 | 53.0 | 41.7 | 38.7 |
31.25 | 23.6 | 10.7 | 540.0 | 45.0 | 52.0 | 50.0 | 37.9 | 34.9 |
62.5 | 21.5 | 15.4 | 539.0 | 45.0 | 47.0 | 45.0 | 31.8 | 28.8 |
100 | 20.1 | 19.8 | 538.0 | 45.0 | 44.3 | 42.3 | 27.8 | 24.8 |
200 | 18.0 | 29.0 | 537.0 | 45.0 | 39.7 | 37.7 | 21.7 | 18.7 |
250 | 17.3 | 32.8 | 536.0 | 45.0 | 38.0 | 36.0 | 19.8 | 16.8 |
Note: The above transmission performance tor the 100M, 20±2ºC under the conditions tested. | ||||||||
Order Informations | ||||||||
Marking | U/UTP CAT6 4PR 23AWG PVC XXX (or Per customer’s request) | |||||||
Inner Package | 305m/Spool,305m/Reel (or Per customer’s request) | |||||||
Outer Package | Color Box, Palette (or Per customer’s request) | |||||||
Delivery time | Normally 25 days after received the deposit. |