Dlo Diesel Locomotive Cable 1 AWG, 2000V Flexible Tinned Copper Conductor Electric Wire

Model NO.
Diesel Locomotive Cable, DLO Cable

Wire Core Material
Tinned Wire

Certification
ISO, CCC, RoHS, UL

Model
Diesel Locomotive Cable, Dlo

Brand
Renda

Products Name
Diesel Locomotive Cable, Dlo Cable

UL Listed Type
Type Rhh-Rhw-2, Type Dlo Cable

Standard
UL2806, UL44

Rated Voltage
600V, 2000V

Insulation
Epr, EPDM, Ep

Sheath
CPE, Sun Resistance, Oil Resistance

Working Temperture
Max 90 Degree or 105degre

RoHS
Yes

Msha Approved
Yes

Character
Resists Oils, Acids, Alkalies, Heat

Trademark
RENDA

Transport Package
Roll, Reel, Coil as Your Requirements

Specification
12AWG, 10AWG TO 1111.1Kcmil

Origin
China

HS Code
8544492100

Description

DLO Diesel Locomotive Cable  1 AWG,
2000V Flexible Tinned Copper Conductor
 Dlo Diesel Locomotive Cable 1 AWG, 2000V Flexible Tinned Copper Conductor Electric Wire

APPLICATION
DLO is used in a variety of applications by several industries. The extra flexible tinned copper conductor has a suitable separator on sizes 4 AWG and larger. Insulated and jacketed with a crosslinked EPR thermosetting insulation and jacket, Cobra DLO meets the requirements of ICEA S-68-516 providing toughness along with good flexibility. This cable passes the MSHA Flame Test with a continuous rating of 90°C. Cable complies with UL Standards 44 & 1581.
 

Applications
  • Drilling rigs, both on-shore and off-shore
  • Railroad and transit cars
  • Electric earth-moving equipment
  • Shipyard machinery and equipment 
  • Supply leads for arc welders
  • Power and control jumper cable
  • Motor leads

STANDARDS & REFERENCES
Type DLO Cable meets or exceeds the applicable requirements of the following standards and
specifications:

RoHS Compliant
MSHA accepted 
UL listed as Type RHH-RHW-2 per UL 44
Flexible strand tin coated copper conductor, B-172, ASTM B-33
UL listed as per UL 2806

Meets FT-4 Flame Tests

DLO offers:
90°C temperature rating
Excellent impact and abrasion resistance
Resists oils, acids, alkalies, heat and flame
The flexible tinned copper stranding

CONSTRUCTION
Conductor: Stranded Tinned Copper, Fully Annealed per AAR-598 and ASTM B 33
Insulation: Premium-grade Ethylene Propylene Rubber (EPR)
Cable Jacket: Black Chlorinated Polyethylene (CPE)
Temperature Range: -40°C to +90°C
Voltage Rating: 600 Volts ,1000V,2000V
 

SIZE      AWG     KcmilCONDUCTORPOLYESTER FILMINSULATIONJACKETNOMINAL
OVERALL
DIAMETER
WEIGHT
COND STRANDDia.NOMINAL
THICKNESS
NOMINAL INSULATION
THICKNESS
NOMINAL JACKET
THICKNESS
 MMMMMMMMMMMMKG/KM
121×37/0.3732.61 0.051.520.386.686.6
101×27/0.472.81 0.051.520.386.894.6
81×37/0.5113.58 0.051.780.768.8154.2
61×61/0.5114.60 0.051.780.769.8213.1
47×15/0.5116.53 0.051.780.7611.8322.2
37×19/0.5117.36 0.051.780.7612.6386.2
27×23/0.5118.11 0.051.780.7613.3449.0
17×30/0.5119.27 0.052.291.1416.3621.3
1/019×14/0.51110.50 0.052.291.1417.5748.5
2/019×18/0.51111.93 0.052.291.1418.9916.7
3/019×22/0.51113.21 0.052.291.1420.21082.2
4/019×28/0.51114.92 0.052.291.1421.91326.9
262.619×34/0.51116.45 0.052.671.6525.21669.4
313.319×41/0.51118.08 0.052.671.6526.91955.0
373.719×49/0.51119.78 0.052.671.6528.62277.8
444.419×58/0.51121.52 0.052.671.6530.32637.5
535.319×70/0.51123.65 0.053.051.6533.23171.0
646.437×43/0.51125.93 0.053.051.6535.53715.5
777.737×52/0.51128.52 0.053.051.6538.14403.1
929.961×38/0.51131.32 0.053.051.6540.95210.2
1111.161×45/0.51134.10 0.053.562.4146.26343.0
 
Dlo Diesel Locomotive Cable 1 AWG, 2000V Flexible Tinned Copper Conductor Electric Wire
UL Certificate for SOOW CORDS, XHHW,DLO,SEU,MC Cable
Dlo Diesel Locomotive Cable 1 AWG, 2000V Flexible Tinned Copper Conductor Electric Wire
Dlo Diesel Locomotive Cable 1 AWG, 2000V Flexible Tinned Copper Conductor Electric Wire
Dlo Diesel Locomotive Cable 1 AWG, 2000V Flexible Tinned Copper Conductor Electric Wire