Medium Voltage Copper Aluminum Conductor XLPE Insulated Armored Power Cable

Model NO.
YJV32 YJLV32

Wire Core Material
Copper

Certification
ISO, CCC, CE, RoHS, UL, TUV

Model
Yjv32

Brand
Qifan

Engineer No.
206

Plant No.
3 Plant with 12 Workshop

Sample Free
Yes

Trademark
QIFAN

Transport Package
Drums

Specification
25-1600mm2

Origin
China

HS Code
85444921

Description

Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated Armored Power Electric Cable 
 
Product Standard
This product is manufactured according to GB/T12706.2, equivalent to IEC60502.2. Or BS, DIN, ICEA standard as customer request.  
 Application
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.
3 Operating characteristics
– Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
– Max.admissible operating temperature of the conductor:90ºC.
– Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
– The ambient temperature under installation should not below 00C.
– The bending radius of a single-core cable should not less than 20 times of the cable diameter. 
The bending radius of a multi-core cable should not less than 15 times of the cable diameter. 

Table of the voltage, cores and cross-section

ItemCategory    A ,B3.6/6kV6/10kV8.7/15kV12/20kV18/30kV21/35kV
Category    A ,B6/6kV8.7/10kV12/15kV18/20kV26/35kV
Single coremm225-120025-120035-120050-120050-120050-1200
Three coremm225-40025-40035-40050-40050-40050-400

The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.

Type and Name

TypeDesignationApplications
YJVCopper conductor,XLPE insulated,PVC sheathed power cableFor laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLVAluminum conductor,XLPE insulated,PVC sheathed power cable
YJYCopper conductor, XLPE insulated,PE sheathed power cable
YJLYAluminum conductor, XLPE insulated,PE sheathed power cable
YJV22Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cableFor laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV22Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable
YJV23Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJLV23Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJV32Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cableFor laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force.
YJLV32Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable
YJV33Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
YJLV33Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable

 Medium Voltage Copper Aluminum Conductor XLPE Insulated Armored Power CableMedium Voltage Copper Aluminum Conductor XLPE Insulated Armored Power CableMedium Voltage Copper Aluminum Conductor XLPE Insulated Armored Power CableMedium Voltage Copper Aluminum Conductor XLPE Insulated Armored Power CableMedium Voltage Copper Aluminum Conductor XLPE Insulated Armored Power CableMedium Voltage Copper Aluminum Conductor XLPE Insulated Armored Power Cable