Yjv Yjv22 Yjv32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage
Model NO.
low voltage cable
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS, UL, VDE
Model
VV, Yjv…
Brand
Chang Qing Teng
Product Name
Low Voltage Cable/ PVC Cable/ XLPE Cable/ Armoured
Number of Cores
Single/2/3/4/5/6/7/8/10/16 Core…
Cross Section Area/Measure
3.5/4/6/10/16/25/35/50/70/95/120/150/185/240/300/4
Standard
IEC 60502-1, BS 7870-6, BS 6622, BS 7835, GB 5023-
Conductor
Stranded/Solid/Flexible Copper/Aluminum Conductor
Insulation
XLPE/PVC/PE/PUR
Aplication
Electric, House Wire, Building Wire…
Shield
Copper Wire Screen(Cws), Aluminium Wire Screen(Aws
Armoured
Steel Tape Armoured (Sta) or Steel Wire Armoured (
Trademark
Luxing
Transport Package
Non-Fumigation Wooden Drum, Iron-Wooden Drum.
Specification
350x160x270,800x350x550,1000x500x600,1200x500x900.
Origin
Shandong
HS Code
8544492100
Description
YJV YJV22 YJV32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage
1.Applications
-These cables are used for electricity supply in low voltage installation system.
-They are suitable for installation in indoors and outdoors,in cable ducts, underground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.
2.Construction
–Conductors
The conductors shall be either of Class 1 or Class 2 of plain accordance with IEC 60228.
–Insulation
PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.
–Assembly / Inner Covering
The inner coverings may be extruded or lapped.
–Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
–Outer Sheath
Outer sheath shall be of extruded PVC as per IEC 60502-1, Polyethylene, Halogen free compound.
Polychloroprene, chlorosulfonated polyethylene or similar polymers.
–Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
3.Parameters
Single core(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
1×4 | 2.3 | 1 | 1.4 | 7.1 | ||
1×6 | 2.8 | 1 | 1.4 | 7.6 | ||
1×10 | 3.6 | 1 | 1.4 | 8.4 | ||
1×16 | 4.5 | 1 | 1.4 | 9.3 | ||
1×25 | 5.6 | 1.2 | 1.4 | 10.8 | ||
1×35 | 6.7 | 1.2 | 1.4 | 11.9 | ||
1×50 | 8 | 1.4 | 1.4 | 13.6 | ||
1×70 | 9.4 | 1.4 | 1.4 | 15.1 | ||
1×95 | 11 | 1.6 | 1.5 | 17.2 | ||
1×120 | 12.4 | 1.6 | 1.5 | 18.7 | ||
1×150 | 13.8 | 1.8 | 1.6 | 20.6 | ||
1×185 | 15.3 | 2 | 1.7 | 22.7 | ||
1×240 | 17.5 | 2.2 | 1.8 | 25.4 | ||
1×300 | 19.5 | 2.4 | 1.9 | 28.0 | ||
1×400 | 22.6 | 2.6 | 2.0 | 31.7 | ||
1×500 | 25.2 | 2.8 | 2.1 | 35.0 | ||
1×630 | 28.3 | 2.8 | 2.2 | 38.3 |
Two cores(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
2×1.5 | 1.4 | 0.8 | 1.8 | 9.6 | ||
2×2.5 | 1.8 | 0.8 | 1.8 | 10.4 | ||
2×4 | 2.3 | 1 | 1.8 | 12.2 | ||
2×6 | 2.8 | 1 | 1.8 | 13.2 | ||
2×10 | 3.6 | 1 | 1.8 | 14.8 | ||
2×16 | 4.5 | 1 | 1.8 | 16.6 | ||
2×25 | 5.6 | 1.2 | 1.8 | 19.6 | ||
2×35 | 6.7 | 1.2 | 1.8 | 21.8 | ||
2×50 | 8 | 1.4 | 1.8 | 25.2 | ||
2×70 | 9.4 | 1.4 | 1.9 | 28.1 | ||
2×95 | 11 | 1.6 | 2.0 | 32.4 | ||
2×120 | 12.4 | 1.6 | 2.1 | 35.4 | ||
2×150 | 13.8 | 1.8 | 2.2 | 39.2 | ||
2×185 | 15.3 | 2 | 2.4 | 43.3 | ||
2×240 | 17.5 | 2.2 | 2.5 | 48.9 | ||
2×300 | 19.5 | 2.4 | 2.7 | 54.0 | ||
2×400 | 22.6 | 2.6 | 2.9 | 61.5 |
Three cores(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
3×1.5 | 1.4 | 0.8 | 1.8 | 10.1 | ||
3×2.5 | 1.8 | 0.8 | 1.8 | 10.9 | ||
3×4 | 2.3 | 1 | 1.8 | 12.9 | ||
3×6 | 2.8 | 1 | 1.8 | 13.9 | ||
3×10 | 3.6 | 1 | 1.8 | 15.7 | ||
3×16 | 4.5 | 1 | 1.8 | 17.6 | ||
3×25 | 5.6 | 1.2 | 1.8 | 20.8 | ||
3×35 | 6.7 | 1.2 | 1.8 | 23.2 | ||
3×50 | 8 | 1.4 | 1.8 | 26.9 | ||
3×70 | 9.4 | 1.4 | 1.9 | 30.1 | ||
3×95 | 11 | 1.6 | 2.1 | 34.7 | ||
3×120 | 12.4 | 1.6 | 2.2 | 38.0 | ||
3×150 | 13.8 | 1.8 | 2.3 | 42.1 | ||
3×185 | 15.3 | 2 | 2.5 | 46.5 | ||
3×240 | 17.5 | 2.2 | 2.7 | 52.5 | ||
3×300 | 19.5 | 2.4 | 2.8 | 58.0 | ||
3×400 | 22.6 | 2.6 | 3.1 | 66.1 |
Three cores+1(unarmoured) | ||||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||||
mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm | ||
3x 16/10 | 4.5 | 3.6 | 1 | 1 | 1.8 | 19.0 | ||
3x 25/16 | 5.6 | 4.5 | 1.2 | 1 | 1.8 | 22.6 | ||
3x 35/16 | 6.7 | 4.5 | 1.2 | 1 | 1.8 | 25.3 | ||
3x 50/25 | 8.0 | 5.6 | 1.4 | 1.2 | 1.9 | 29.6 | ||
3x 70/35 | 9.4 | 6.7 | 1.4 | 1.2 | 2.0 | 33.2 | ||
3x 95/50 | 11.0 | 8.0 | 1.6 | 1.4 | 2.2 | 38.4 | ||
3×120/70 | 12.4 | 9.4 | 1.6 | 1.4 | 2.3 | 42.0 | ||
3×150/70 | 13.8 | 9.4 | 1.8 | 1.4 | 2.5 | 46.6 | ||
3×185/95 | 15.3 | 11.0 | 2 | 1.6 | 2.6 | 51.6 | ||
3×240/120 | 17.5 | 12.4 | 2.2 | 1.6 | 2.9 | 58.3 | ||
3×300/150 | 19.5 | 13.8 | 2.4 | 1.8 | 3.1 | 64.5 | ||
3×400/185 | 22.6 | 15.3 | 2.6 | 2 | 3.3 | 73 |
Four cores(unarmored) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
4×1.5 | 1.4 | 0.8 | 1.8 | 10.8 | ||
4×2.5 | 1.8 | 0.8 | 1.8 | 11.8 | ||
4×4 | 2.3 | 1 | 1.8 | 14.0 | ||
4×6 | 2.8 | 1 | 1.8 | 15.2 | ||
4×10 | 3.6 | 1 | 1.8 | 17.1 | ||
4×16 | 4.5 | 1 | 1.8 | 19.3 | ||
4×25 | 5.6 | 1.2 | 1.8 | 22.9 | ||
4×35 | 6.7 | 1.2 | 1.8 | 25.6 | ||
4×50 | 8 | 1.4 | 1.9 | 29.9 | ||
4×70 | 9.4 | 1.4 | 2.0 | 33.5 | ||
4×95 | 11 | 1.6 | 2.2 | 38.7 | ||
4×120 | 12.4 | 1.6 | 2.3 | 42.3 | ||
4×150 | 13.8 | 1.8 | 2.5 | 46.9 | ||
4×185 | 15.3 | 2 | 2.6 | 51.9 | ||
4×240 | 17.5 | 2.2 | 2.9 | 58.6 | ||
4×300 | 19.5 | 2.4 | 3.1 | 64.8 | ||
4×400 | 22.6 | 2.6 | 3.3 | 73.8 |
Multi-cores(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
5×1.5 | 1.4 | 0.8 | 1.8 | 11.7 | ||
7×1.5 | 1.4 | 0.8 | 1.8 | 12.6 | ||
10×1.5 | 1.4 | 0.8 | 1.8 | 15.6 | ||
12×1.5 | 1.4 | 0.8 | 1.8 | 16.1 | ||
14×1.5 | 1.4 | 0.8 | 1.8 | 16.8 | ||
19×1.5 | 1.4 | 0.8 | 1.8 | 18.6 | ||
21×1.5 | 1.4 | 0.8 | 1.8 | 19.5 | ||
24×1.5 | 1.4 | 0.8 | 1.8 | 21.6 | ||
30×1.5 | 1.4 | 0.8 | 1.8 | 22.8 | ||
40×1.5 | 1.4 | 0.8 | 1.8 | 27.7 | ||
48×1.5 | 1.4 | 0.8 | 1.9 | 28.2 | ||
61×1.5 | 1.4 | 0.8 | 1.9 | 30.9 | ||
5×2.5 | 1.8 | 0.8 | 1.8 | 12.8 | ||
7×2.5 | 1.8 | 0.8 | 1.8 | 13.8 | ||
10×2.5 | 1.8 | 0.8 | 1.8 | 17.2 | ||
12×2.5 | 1.8 | 0.8 | 1.8 | 17.7 | ||
14×2.5 | 1.8 | 0.8 | 1.8 | 18.6 | ||
19×2.5 | 1.8 | 0.8 | 1.8 | 20.6 | ||
21×2.5 | 1.8 | 0.8 | 1.8 | 21.6 | ||
24×2.5 | 1.8 | 0.8 | 1.8 | 24.0 | ||
30×2.5 | 1.8 | 0.8 | 1.8 | 25.4 | ||
40×2.5 | 1.8 | 0.8 | 2.0 | 31.1 | ||
48×2.5 | 1.8 | 0.8 | 2.0 | 31.7 | ||
61×2.5 | 1.8 | 0.8 | 2.1 | 34.7 |