Flexible Solid Stranded Copper Aluminium PVC Insulated Electric Wire
Modelo NÃO.
BV BLV BVV RV RVV
Material Shape
Round or Flat
Range of Application
Building
Certificação
ISO 9001, CE, CCC
Brand
Yifang
Voltage
Under 1 Kv
Uso
for House Building or Factory Building
Core
Single or Multicore
Cor
Vermelho, Yellow, Green, Blue, Preto, Yellow/Green etc
Standard
IEC60227 or as Per Customer Request
Marca comercial
YIFANG
Pacote de transporte
Coils, Rolls or Drums
Especificação
0.12 to 400mm2
Origem
China
Código HS
8544492100
Descrição
Flexible Solid Stranded Copper Aluminium PVC Insulated Electric Wire Cable
1.Inscrição:
Fixed wiring,civil power,mobile equipment
2.Construction
Conductor type:
IEC 60228-2004 class 1 or class 2.
Nominal Cross-section area: 0.5~400mm2
We can according to our client’s need and also provide technical data
Nominal Cross-section area: 0.5~400mm2
We can according to our client’s need and also provide technical data
3.Characteristic
Rated Voltage:
450/750V More-than 1.5mm2 single core conductor
300/500V Less-than 1.5mm2 single core and multicore conductor
300/300VLess-than 1.5mm2 multicore conductor
Test Voltage:
AC 1500V/5Min for 0.5~1mm2 multicore conductor
AC 2000V/5Min for 0.5~1mm2 single core and multicore conductor
AC 2500V/5Min Other.
Color of Insulation:
Vermelho,Yellow,Green,Light blue,Branco,Preto,Grey,Brown,Orange,Violet,Yellow/Green.
Notes
1, Ambient temperature for insulation shall not be lower than 0ºC.
2, At nominal conditions, the conductor’s operating temperature is -15ºC to +70ºC
3, Fire resistant wire conform to IEC 60331-2009, Flame resistant wire conform to IEC 60332-2004.
4.Standard
IEC 60227-2007 or as per customer’s request
Some Type (Remarks: we can design and produce according to customer’s request.)
Some Type (Remarks: we can design and produce according to customer’s request.)
Modelo | Nome | Laying Site and Requirements | Long-time Permissible Working Temperature of Conductor(C) |
227IEC01/05 BV BLV | Copper Conductor,PVC Insulated Wire | Fixed laid in the circumstance of indoor, conduit etc. | 70 |
Aluminium Conductor,PVC Insulated Wire | |||
227IEC 07 BV-90 | Heat Resistant Copper Conductor,PVC Insulated Wire at 90C | Fixed laid in the circumstance of high temperature environment and can be laid indoor, conduit etc. | 90 |
BVR | Copper Conductor,PVC Insulated Flexible Wire | Fixed laid where flexibility is required. | 70 |
227-IEC10 BVV | Copper Conductor PVC Insulated and PVC Sheathed Round Wire | Fixed laid where high mechanical protection and moisture are required. They can be laid in the air or underground. | 70 |
BLVV | Aluminium Conductor PVC Insulated and PVC Sheathed Round Wire | ||
BVVB | Copper Conductor PVC Insulated and PVC Sheathed Flat Wire | ||
BLVVB | Aluminium Conductor PVC Insulated and PVC Sheathed Flat Wire | ||
227IEC 02 RV227 IEC 06 RV | Copper Conductor,PVC Insulated Flexible Connector | Mainly used at middle-light type movable euipments, instrument and meters, household appliances, power and lighting and the places where flexibility is required. | 70 |
227IEC 42 RVB | Copper Conductor,PVC Insulated Flat Flexible Connector | ||
RVS | Copper Conductor,PVC Insulated Flexible Twisting Connector | ||
227IEC52 RVV 227IEC53 RVV | Copper Conductor PVC Insulated and PVC Sheathed Round Flexible Connector(Light and Common Type) |
5. Picture