UC3 Single Phase Motor Control 100A Power Latching Meter Relay

Modelo NÃO.
IM-M1202

Protective Characteristics
Sealed Relay

Action Principle
Electromagnetic Type

Tamanho
Miniature

Modelo
Electric Parameter Relay

Nome do Produto
Mini Motor Control 100A Power Latching Relay

Contact Material
Agsno2

Rated Load
100UMA, 250VAC

Coil Voltage
12VDC

Cor
Preto

Marca comercial
IVY

Pacote de transporte
Cartons/Pallet

Especificação
29*23.5*16milímetros

Origem
Zhejiang, China

Código HS
8536411000

Categorias: ,

Descrição


UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay

Basic DatumaDimensions(milímetros)29×23.5×16
Peso ( g )≈40g
Contact Arrangement1A/1B
Contact MaterialAgSnO2
Ambient Temperature40~+75C
Vibration10~50Hz,1.5milímetros
Shock1000m/s²,(100g)
Specifications DatumaPower Consumption<3W
Operating Voltage10.5-16V
Máx.. Switching Current100UMA
Surge Current6000A/10ms
Motor Resistance32(1±15%)Ω
Contact Voltage<60mV
Contact Resistance≤1.0
Dielectric StrengthMotor to Contact>4000VAC,50/60Hz 1min
Across Open Contact>2000VAC,50/60Hz 1min
Electrical Life(120 cycles/H)10,000
(resistência 5 k + perceptual 5 k, co ϕ = 0.5)
Mechanical Life(3600 cycles/H)100,000
Pulse Time60ms(Advise 60ms~100ms)
Picking-up Time≤60ms
Release Time≤60ms
Insulation Resistance>1000(500VDC)

UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
UC3 Single Phase Motor Control 100A Power Latching Meter Relay
Cautions of Latching Relay:

1.Suggestions of relay’s input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then”+ -” or “- +”are fine,

you can change it by one pulse.If double coil then it’s necessary to confirm “-+-” or “+-+”before leaving the our factory.
(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays’contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
2.Suggestions of relay’s output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
the installation.
(2)When the relay will be connected with screw or bolts to the relaysterminals, plz make sure your connection is
fastened and prevent relay from damages or other safety problems due to temp. Rise..
(3)The sampling signal wires of products are limited, please do not pull or torque during installation.